Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 309
Filtrar
1.
Heart Rhythm ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38604592

RESUMO

BACKGROUND: The utility of atrioventricular (AV) optimization (AVO) algorithms remains in question. A substudy of the SMART-AV trial found that patients with prolonged interventricular delays ≥70 ms were more likely to benefit from cardiac resynchronization therapy (CRT) with AVO. The SMART-CRT trial evaluated AVO on the basis of these results, but the study was underpowered. OBJECTIVE: To increase statistical power, data from SMART-AV patients meeting the inclusion criterion of interventricular delay ≥70 ms were pooled with data from SMART-CRT to reassess AVO. METHODS: SMART-CRT and SMART-AV were prospective, randomized, multicenter clinical trials. Patients in both studies were randomized to be programmed with an AVO algorithm (SmartDelay) or fixed AV delay (120 ms). Paired echocardiograms obtained at baseline and 6 months were compared, with CRT response defined as ≥15% reduction in left ventricular end-systolic volume. RESULTS: A total of 451 complete patient data sets were pooled and analyzed. The baseline demographics between studies did not differ statistically in terms of age, sex, left ventricular ejection fraction, or left ventricular end-systolic volume. The AVO group had a greater proportion of CRT responders (SmartDelay, 73.9%; fixed, 63.1%; P = .014) and greater changes in measures of reverse remodeling. SmartDelay patients with a recommended sensed AV delay outside the nominal range (100-120 ms) had 2.3 greater odds of CRT response than fixed AV delay patients. CONCLUSION: Greater CRT response and measures of reverse remodeling were observed in patients with SmartDelay enabled vs a fixed AV delay. This study supports the use of SmartDelay in patients with a CRT indication and interventricular delay ≥70 ms. GOV REGISTRATION: NCT00677014 and NCT03089281.

4.
J Cardiovasc Electrophysiol ; 35(2): 240-246, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38047465

RESUMO

INTRODUCTION: The pivotal study of the extravascular implantable cardioverter-defibrillator (EV ICD) recently demonstrated primary efficacy and safety endpoints comparable to previous ICD systems. Patient experience with this novel device has not been reported. The current study examined the standardized patient-reported outcome (PRO) metrics of quality of life (QOL) and patient acceptance of the device. METHODS: The EV ICD Pivotal Study was a prospective, single-arm, nonrandomized, global, premarket approval trial. Patients completed the 12-Item Short Form Survey (SF-12) QOL surveys at baseline and at 6 months following implant. Additionally, patients completed the Florida Patient Acceptance Survey (FPAS) QOL survey at 6 months. RESULTS: From baseline to 6 months, patients within the EV ICD Pivotal Study (n = 247) reported statistically significant SF-12 improvements in physical QOL (45.4 ± 9.4 vs. 46.8 ± 9.1 respectively, p = .020) and no changes in mental QOL (49.3 ± 10.4 vs. 50.5 ± 9.7, p = .061). No differences were noted by sex, atrial fibrillation, or the experience of ICD shock. EV ICD patients reported better total FPAS patient acceptance of their ICD than TV-ICD or S-ICD patients using historical norms comparisons (80.4 ± 15.7 vs. 70.2 ± 17.8, p < .0001 for S-ICD and 73.0 ± 17.4, p = .004 for TV-ICD). CONCLUSION: The initial PROs for EV ICD patients indicated that patients had improvements in physical QOL from baseline to 6-month follow-up and markedly better overall acceptance of their ICD compared to a previous study with S-ICD and TV-ICD data. These initial results suggest that the EV ICD is evaluated positively by patients.


Assuntos
Desfibriladores Implantáveis , Humanos , Qualidade de Vida , Estudos Prospectivos , Inquéritos e Questionários , Medidas de Resultados Relatados pelo Paciente
5.
Eur Heart J ; 45(5): 346-365, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38096587

RESUMO

The role of cardiac implantable electronic device (CIED)-related tricuspid regurgitation (TR) is increasingly recognized as an independent clinical entity. Hence, interventional TR treatment options continuously evolve, surgical risk assessment and peri-operative care improve the management of CIED-related TR, and the role of lead extraction is of high interest. Furthermore, novel surgical and interventional tricuspid valve treatment options are increasingly applied to patients suffering from TR associated with or related to CIEDs. This multidisciplinary review article developed with electrophysiologists, interventional cardiologists, imaging specialists, and cardiac surgeons aims to give an overview of the mechanisms of disease, diagnostics, and proposes treatment algorithms of patients suffering from TR associated with CIED lead(s) or leadless pacemakers.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Cardiopatia Reumática , Insuficiência da Valva Tricúspide , Humanos , Marca-Passo Artificial/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/complicações , Cardiopatia Reumática/complicações , Estudos Retrospectivos
7.
medRxiv ; 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38106113

RESUMO

Background: Studies have reported that female sex predicts superior cardiac resynchronization therapy (CRT) response. One theory is that this association is related to smaller female heart size, thus increased "relative dyssynchrony" at given QRS durations (QRSd). Objective: To investigate the mechanisms of sex-specific CRT response relating to heart size, relative dyssynchrony, cardiomyopathy type, QRS morphology, and other patient characteristics. Methods: A post-hoc analysis of the MORE-CRT MPP trial (n=3739, 28% female), with a sub-group analysis of patients with non-ischaemic cardiomyopathy (NICM) and left bundle branch block (LBBB) (n=1308, 41% female) to control for confounding characteristics. A multivariable analysis examined predictors of response to 6 months of conventional CRT, including sex and relative dyssynchrony, measured by QRSd/LVEDV (left ventricular end-diastolic volume). Results: Females had a higher CRT response rate than males (70.1% vs. 56.8%, p<0.0001). Subgroup analysis: Regression analysis of the NICM LBBB subgroup identified QRSd/LVEDV, but not sex, as a modifier of CRT response (p<0.0039). QRSd/LVEDV was significantly higher in females (0.919) versus males (0.708, p<0.001). CRT response was 78% for female patients with QRSd/LVEDV>median value, compared to 68% < median value (p=0.012). Association between CRT response and QRSd/LVEDV was strongest at QRSd<150ms. Conclusions: In the NICM LBBB population, increased relative dyssynchrony in females, who have smaller heart sizes than their male counterparts, is a driver of sex-specific CRT response, particularly at QRSd <150ms. Females may benefit from CRT at a QRSd <130ms, opening the debate on whether sex-specific QRSd cut-offs or QRS/LVEDV measurement should be incorporated into clinical guidelines.

8.
Panminerva Med ; 2023 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-37851332

RESUMO

BACKGROUND: Increased level of blood LDL-C has a causal and cumulative effect on advancing atherosclerotic cardiovascular diseases (ASCVD). European guidelines for treating high LDL-C levels have been recently updated. However, in France, several challenges (e.g., physician and patient awareness, healthcare management) limit the application of management guidelines. The aim of this study was to understand the current opinions and perceived unmet clinical needs in recognising and managing hypercholesterolemia as an ASCVD risk factor, and to explore consensus around factors that support the effective management of elevated LDL-C. METHODS: An expert group of cardiologists, endocrinologists, biology/genetics researchers, and a health technology assessments expert, from France was convened. The current management of hypercholesterolemia and barriers to achieving LDL-C goals in France were discussed and 44 statements were developed. Wider consensus was assessed by sending the statements as a 4-point Likert Scale questionnaire to cardiologists and endocrinologists across France. The consensus threshold was defined as ≥75%. RESULTS: A total of 101 responses were received. Consensus was very high (>90%) in 25 (57%) statements, high (≥75%) in 18 (41%) statements and was not achieved (<75%) only in 1 (2%) of statements. Overall, 43 statements achieved consensus. CONCLUSIONS: Based on consensus levels, key recommendations for improving current guidelines and approaches to care have been developed. Implementation of these recommendations will lead to better concordance with international treatment guidelines and increase levels of education for healthcare practitioners and patients. In turn, this will improve the available treatment pathways for cardiovascular diseases, potentially creating improved patient outcomes in the future.

9.
Rev. esp. cardiol. (Ed. impr.) ; 76(10): 813-820, Octubre 2023. graf
Artigo em Inglês, Espanhol | IBECS | ID: ibc-226143

RESUMO

El tratamiento de los pacientes con insuficiencia cardiaca con fracción de eyección reducida (IC-FEr) con una combinación de 4 clases de fármacos se recomienda en las principales guías de práctica clínica internacionales. Sin embargo, no especifican cómo deben introducirse y ajustarse estos tratamientos. En consecuencia, muchos pacientes con IC-FEr no pasan a un régimen de tratamiento optimizado. El objetivo de esta revisión es proponer un algoritmo pragmático para optimizar el tratamiento, diseñado para que sea lo más fácil posible de aplicar en la práctica diaria. El primer objetivo es garantizar que las 4 clases de medicación recomendadas se inicien cuanto antes para establecer una terapia eficaz, incluso a dosis bajas. Esto se considera preferible a iniciar menos medicamentos a una dosis máxima. El segundo objetivo es garantizar que los intervalos entre la introducción de los medicamentos y entre los distintos pasos de titulación sean lo más breves posible, por la seguridad del paciente. Se hacen propuestas específicas para los pacientes de edad avanzada (> 75 años) frágiles, y para aquellos con trastornos del ritmo cardiaco. La aplicación de este algoritmo debería permitir alcanzar un protocolo de tratamiento óptimo en un plazo de 2 meses para la mayoría de los pacientes. Este debe ser nuestro objetivo en el tratamiento de la IC-FEr. (AU)


Major international practice guidelines recommend the use of a combination of 4 medication classes in the treatment of patients with heart failure with reduced ejection fraction (HFrEF) but do not specify how these treatments should be introduced and up-titrated. Consequently, many patients with HFrEF do not receive an optimized treatment regimen. This review proposes a pragmatic algorithm for treatment optimization designed to be easily applied in routine practice. The first goal is to ensure that all 4 recommended medication classes are initiated as early as possible to establish effective therapy, even at a low dose. This is considered preferable to starting fewer medications at a maximum dose. The second goal is to ensure that the intervals between the introduction of different medications and between different titration steps are as short as possible to ensure patient safety. Specific proposals are made for older patients (> 75 years) who are frail, and for those with cardiac rhythm disorders. Application of this algorithm should allow an optimal treatment protocol to be achieved within 2-months in most patients, which should the treatment goal in HFrEF. (AU)


Assuntos
Humanos , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/terapia , Guias de Prática Clínica como Assunto , Algoritmos , Otimização de Processos/métodos , Consenso
10.
Europace ; 25(10)2023 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-37776313

RESUMO

AIMS: To assess the impact of MultiPoint™ Pacing (MPP) in cardiac resynchronization therapy (CRT) non-responders after 6 months of standard biventricular pacing (BiVP). METHODS AND RESULTS: The trial enrolled 5850 patients who planned to receive a CRT device. The echocardiography core laboratory assessed CRT response before implant and after 6 months of BiVP; non-response to BiVP was defined as <15% relative reduction in left ventricular end-systolic volume (LVESV). Echocardiographic non-responders were randomized in a 1:1 ratio to receive MPP (541 patients) or continued BiVP (570 patients) for an additional 6 months and evaluated the conversion rate to the echocardiographic response. The characteristics of both groups at randomization were comparable. The percentage of non-responder patients who became responders to CRT therapy was 29.4% in the MPP arm and 30.4% in the BIVP arm (P = 0.743). In patients with ≥30 mm spacing between the two left ventricular pacing sites (MPP-AS), identified during the first phase as a potential beneficial subgroup, no significant difference in the conversion rate was observed. CONCLUSION: Our trial shows that ∼30% of patients, who do not respond to CRT in the first 6 months, experience significant reverse remodelling in the following 6 months. This finding suggests that CRT benefit may be delayed or slowly incremental in a relevant proportion of patients and that the percentage of CRT responders may be higher than what has been described in short-/middle-term studies. MultiPoint™ Pacing does not improve CRT response in non-responders to BiVP, even with MPP-AS.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Resultado do Tratamento , Estudos Prospectivos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Dispositivos de Terapia de Ressincronização Cardíaca , Função Ventricular Esquerda/fisiologia
11.
Lancet ; 402(10408): 1147-1157, 2023 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-37634520

RESUMO

BACKGROUND: Continuous automatic optimisation of cardiac resynchronisation therapy (CRT), stimulating only the left ventricle to fuse with intrinsic right bundle conduction (synchronised left ventricular stimulation), might offer better outcomes than conventional CRT in patients with heart failure, left bundle branch block, and normal atrioventricular conduction. This study aimed to compare clinical outcomes of adaptive CRT versus conventional CRT in patients with heart failure with intact atrioventricular conduction and left bundle branch block. METHODS: This global, prospective, randomised controlled trial was done in 227 hospitals in 27 countries across Asia, Australia, Europe, and North America. Eligible patients were aged 18 years or older with class 2-4 heart failure, an ejection fraction of 35% or less, left bundle branch block with QRS duration of 140 ms or more (male patients) or 130 ms or more (female patients), and a baseline PR interval 200 ms or less. Patients were randomly assigned (1:1) via block permutation to adaptive CRT (an algorithm providing synchronised left ventricular stimulation) or conventional biventricular CRT using a device programmer. All patients received device programming but were masked until procedures were completed. Site staff were not masked to group assignment. The primary outcome was a composite of all-cause death or intervention for heart failure decompensation and was assessed in the intention-to-treat population. Safety events were collected and reported in the intention-to-treat population. This study is registered with ClinicalTrials.gov, NCT02205359, and is closed to accrual. FINDINGS: Between Aug 5, 2014, and Jan 31, 2019, of 3797 patients enrolled, 3617 (95·3%) were randomly assigned (1810 to adaptive CRT and 1807 to conventional CRT). The futility boundary was crossed at the third interim analysis on June 23, 2022, when the decision was made to stop the trial early. 1568 (43·4%) of 3617 patients were female and 2049 (56·6%) were male. Median follow-up was 59·0 months (IQR 45-72). A primary outcome event occurred in 430 of 1810 patients (Kaplan-Meier occurrence rate 23·5% [95% CI 21·3-25·5] at 60 months) in the adaptive CRT group and in 470 of 1807 patients (25·7% [23·5-27·8] at 60 months) in the conventional CRT group (hazard ratio 0·89, 95% CI 0·78-1·01; p=0·077). System-related adverse events were reported in 452 (25·0%) of 1810 patients in the adaptive CRT group and 440 (24·3%) of 1807 patients in the conventional CRT group. INTERPRETATION: Compared with conventional CRT, adaptive CRT did not significantly reduce the incidence of all-cause death or intervention for heart failure decompensation in the included population of patients with heart failure, left bundle branch block, and intact AV conduction. Death and heart failure decompensation rates were low with both CRT therapies, suggesting a greater response to CRT occurred in this population than in patients in previous trials. FUNDING: Medtronic.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Feminino , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Estudos Prospectivos , Resultado do Tratamento , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Volume Sistólico , Eletrocardiografia
12.
Europace ; 25(8)2023 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-37622580

RESUMO

Cardiac resynchronization therapy (CRT) was proposed in the 1990s as a new therapy for patients with heart failure and wide QRS with depressed left ventricular ejection fraction despite optimal medical treatment. This review is aimed first to describe the rationale and the physiologic effects of CRT. The journey of the landmark randomized trials leading to the adoption of CRT in the guidelines since 2005 is also reported showing the high level of evidence for CRT. Different alternative pacing modalities of CRT to conventional left ventricular pacing through the coronary sinus have been proposed to increase the response rate to CRT such as multisite pacing and endocardial pacing. A new emerging alternative technique to conventional biventricular pacing, conduction system pacing (CSP), is a promising therapy. The different modalities of CSP are described (Hirs pacing and left bundle branch area pacing). This new technique has to be evaluated in clinical randomized trials before implementation in the guidelines with a high level of evidence.


Assuntos
Terapia de Ressincronização Cardíaca , Humanos , Volume Sistólico , Função Ventricular Esquerda , Doença do Sistema de Condução Cardíaco , Sistema de Condução Cardíaco
13.
J Am Coll Cardiol ; 82(7): 590-599, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37558371

RESUMO

BACKGROUND: Very few data have been published on the use of subcutaneous implantable cardioverter-defibrillators (S-ICDs) in patients with congenital heart disease (CHD). OBJECTIVES: The aim of this study was to analyze outcomes associated with S-ICDs in patients with CHD. METHODS: This nationwide French cohort including all patients with an S-ICD was initiated in 2020 by the French Institute of Health and Medical Research. Characteristics at implantation and outcomes were analyzed in patients with CHD. RESULTS: From October 12, 2012, to December 31, 2019, among 4,924 patients receiving an S-ICD implant in 150 centers, 101 (2.1%) had CHD. Tetralogy of Fallot, univentricular heart, and dextro-transposition of the great arteries represented almost one-half of the population. Patients with CHD were significantly younger (age 37.1 ± 15.4 years vs 50.1 ± 14.9 years; P < 0.001), more frequently female (37.6% vs 23.0%; P < 0.001), more likely to receive an S-ICD for secondary prevention (72.3% vs 35.9%; P < 0.001), and less likely to have severe systolic dysfunction of the systemic ventricle (28.1% vs 53.1%; P < 0.001). Over a mean follow-up period of 1.9 years, 16 (15.8%) patients with CHD received at least 1 appropriate shock, with all shocks successfully terminating the ventricular arrhythmia. The crude risk of appropriate S-ICD shock was twice as high in patients with CHD compared with non-CHD patients (annual incidences of 9.0% vs 4.4%; HR: 2.1; 95% CI: 1.3-3.4); however, this association was no longer significant after propensity matching (especially considering S-ICD indication, P = 0.12). The burden of all complications (HR: 1.2; 95% CI: 0.7-2.1; P = 0.4) and inappropriate shocks (HR: 0.9; 95% CI: 0.4-2.0; P = 0.9) was comparable in both groups. CONCLUSIONS: In this nationwide study, patients with CHD represented 2% of all S-ICD implantations. Our findings emphasize the effectiveness and safety of S-ICD in this particularly high-risk population. (S-ICD French Cohort Study [HONEST]; NCT05302115).


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Transposição dos Grandes Vasos , Humanos , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Estudos de Coortes , Resultado do Tratamento , Estudos Retrospectivos , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/terapia
14.
J Cardiovasc Med (Hagerstown) ; 24(7): 453-460, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37285276

RESUMO

BACKGROUND: The noninferiority of left ventricular pacing alone (LVp) compared with biventricular pacing (BIV) has not been yet definitely documented. In this study, we reviewed all the original echocardiographic measures of the Biventricular versus Left Univentricular Pacing with ICD Back-up in Heart Failure Patients (B-LEFT HF) trial in order to investigate mechanisms underlying LV remodelling with both pacing modalities. METHODS: Patients with New York Heart Association functional class (NYHA) III or IV despite optimal medical therapy, LVEF 35% or less, left ventricular end-diastolic diameter (LVEDD) more than 55 mm, QRS duration at least 130 ms were randomized to BIV or LVp for 6 months. The primary end point was a composite of at least 1 point decrease in NYHA class and at least 5 mm decrease in left ventricular end-systolic diameter (LVESD). An additional end point was a LVp reverse remodelling defined as at least 10% decrease in LVESD. Mitral regurgitation and all echocardiographic measures were reassessed after 6-month follow-up. RESULTS: One hundred and forty-three patients were enrolled. Seventy-six patients were in the BIV and 67 were in the LVp group. Left ventricular volumes decreased significantly without difference between groups (P = 0.8447). Similarly, left ventricular diameters decreased significantly in both groups with a significant decrease in LVESD with BIV (P < 0.0001), but not with LVp (P = 0.1383). LVEF improved in both groups without difference (P = 0.8072). Mitral regurgitation did not improve either with BIV, or with LVp. CONCLUSION: The echocardiographic sub-analysis of B-LEFT study showed the substantial equivalence of LVp in favouring left ventricular reverse remodelling as compared with BIV.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Insuficiência da Valva Mitral , Humanos , Estimulação Cardíaca Artificial , Insuficiência da Valva Mitral/terapia , Volume Sistólico , Ecocardiografia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Terapia de Ressincronização Cardíaca/efeitos adversos , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto
15.
Circ Arrhythm Electrophysiol ; 16(6): e011714, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37183700

RESUMO

BACKGROUND: The role of atrioventricular optimization (AVO) to improve cardiac resynchronization therapy outcomes remains controversial. Previous post hoc analyses of a multicenter trial showed that measures of electrical dyssynchrony (right ventricular-left ventricular [LV] or LV electrical delay durations) are associated with patients who benefit from AVO. METHODS: This was a global, multicenter, prospective, randomized trial of de novo cardiac resynchronization therapy implant patients with an right ventricular-LV duration ≥70 ms to determine whether AVO results in greater reverse remodeling. Patients were randomized 1:1 for either an AVO algorithm (SmartDelay) that determines atrioventricular delay and pacing chamber, biventricular or LV only, or a fixed atrioventricular delay of 120 ms with biventricular pacing. Paired echocardiograms performed at baseline and 6 months were evaluated. The primary end point was echocardiographic cardiac resynchronization therapy response, defined dichotomously as a >15% reduction in LV end-systolic volume. RESULTS: A total of 310 patients (n=120 women) were randomized and had completed 6 months of follow-up. The echocardiographic cardiac resynchronization therapy response rate did not statistically differ between the groups (SmartDelay, 74.8%; fixed, 67.7%; P=0.17). Analyses of prespecified secondary end points demonstrated significant improvements in the absolute (median: SmartDelay, -41.0 mL; fixed, -33.0 mL; P=0.01) and relative change in LV end-systolic volume (SmartDelay, -38.3%; fixed, -27.8%; P=0.03) for patients with SmartDelay optimization. Similar results were observed for the relative improvement in LV ejection fraction (SmartDelay, 46.7%; fixed, 32.1%; P=0.050); absolute improvement in LV ejection fraction trended to be higher with SmartDelay (P=0.06). CONCLUSIONS: Analysis of reverse remodeling parameters demonstrated that AVO via SmartDelay, relative to the nonoptimized fixed atrioventricular delay comparator group, improved absolute and relative changes in LV function in patients with longer right ventricular-LV duration. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT03089281.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Feminino , Terapia de Ressincronização Cardíaca/métodos , Estudos Prospectivos , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Função Ventricular Esquerda/fisiologia , Remodelação Ventricular/fisiologia
16.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37021342

RESUMO

AIMS: While elevated resting heart rate measured at a single point of time has been associated with cardiovascular outcomes, utility of continuous monitoring of nocturnal heart rate (NHR) has never been evaluated. We hypothesized that dynamic NHR changes may predict, at short term, impending cardiovascular events in patients equipped with a wearable cardioverter-defibrillator (WCD). METHODS AND RESULTS: The WEARIT-France prospective cohort study enrolled heart failure patients with WCD between 2014 and 2018. Night-time was defined as midnight to 7 a.m. NHR initial trajectories were classified into four categories based on mean NHR in the first week (High/Low) and NHR evolution over the second week (Up/Down) of WCD use. The primary endpoint was a composite of cardiovascular death and heart failure hospitalization. A total of 1013 [61 (interquartile range, IQR 53-68) years, 16% women, left ventricular ejection fraction 26% (IQR 22-30)] were included. During a median WCD wear duration of 68 (IQR 44-90) days, 58 patients (6%) experienced 69 events. After considering potential confounders, High-Up NHR trajectory was significantly associated with the primary endpoint compared to Low-Down [adjusted hazard ratio (HR) 6.08, 95% confidence interval (CI) 2.56-14.45, P < 0.001]. Additionally, a rise of >5 bpm in weekly average NHR from the preceding week was associated with 2.5 higher composite event risk (HR 2.51, 95% CI 1.22-5.18, P = 0.012) as well as total mortality (HR 11.21, 95% CI 3.55-35.37, P < 0.001) and cardiovascular hospitalization (HR 2.70, 95% CI 1.51-4.82, P < 0.001). CONCLUSION: Dynamic monitoring of NHR may allow timely identification of impending cardiovascular events, with the potential for 'pre-emptive' action. REGISTRATION NUMBER: Clinical Trials.gov Identifier: NCT03319160.


Assuntos
Insuficiência Cardíaca , Dispositivos Eletrônicos Vestíveis , Humanos , Feminino , Masculino , Estudos de Coortes , Frequência Cardíaca , Estudos Prospectivos , Volume Sistólico/fisiologia , Função Ventricular Esquerda , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Desfibriladores
17.
Front Cardiovasc Med ; 10: 1111538, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37063957

RESUMO

Cardiac resynchronisation therapy (CRT) has an established role in the management of patients with heart failure, reduced left ventricular ejection fraction (LVEF < 35%) and widened QRS (>130 msec). Despite the complex pathophysiology of left ventricular (LV) dyssynchrony and the increasing evidence supporting the identification of specific electromechanical substrates that are associated with a higher probability of CRT response, the assessment of LVEF is the only imaging-derived parameter used for the selection of CRT candidates. This review aims to (1) provide an overview of the evolution of cardiac imaging for the assessment of LV dyssynchrony and its role in the selection of patients undergoing CRT; (2) highlight the main pitfalls and advantages of the application of cardiac imaging for the assessment of LV dyssynchrony; (3) provide some perspectives for clinical application and future research in this field. Conclusion: the road for a more individualized approach to resynchronization therapy delivery is open and imaging might provide important input beyond the assessment of LVEF.

19.
Rev Esp Cardiol (Engl Ed) ; 76(10): 813-820, 2023 Oct.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36914024

RESUMO

Major international practice guidelines recommend the use of a combination of 4 medication classes in the treatment of patients with heart failure with reduced ejection fraction (HFrEF) but do not specify how these treatments should be introduced and up-titrated. Consequently, many patients with HFrEF do not receive an optimized treatment regimen. This review proposes a pragmatic algorithm for treatment optimization designed to be easily applied in routine practice. The first goal is to ensure that all 4 recommended medication classes are initiated as early as possible to establish effective therapy, even at a low dose. This is considered preferable to starting fewer medications at a maximum dose. The second goal is to ensure that the intervals between the introduction of different medications and between different titration steps are as short as possible to ensure patient safety. Specific proposals are made for older patients (> 75 years) who are frail, and for those with cardiac rhythm disorders. Application of this algorithm should allow an optimal treatment protocol to be achieved within 2-months in most patients, which should the treatment goal in HFrEF.


Assuntos
Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Insuficiência Cardíaca/tratamento farmacológico , Volume Sistólico
20.
Europace ; 25(1): 199-210, 2023 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-36753478

RESUMO

To develop a suite of quality indicators (QIs) for the management of patients with ventricular arrhythmias (VA) and the prevention of sudden cardiac death (SCD). The Working Group comprised experts in heart rhythm management including Task Force members of the 2022 European Society of Cardiology (ESC) Clinical Practice Guidelines for the management of patients with VA and the prevention of SCD, members of the European Heart Rhythm Association, international experts, and a patient representative. We followed the ESC methodology for QI development, which involves (i) the identification of the key domains of care for the management of patients with VA and the prevention of SCD by constructing a conceptual framework of care, (ii) the development of candidate QIs by conducting a systematic review of the literature, (iii) the selection of the final set of QIs using a modified-Delphi method, and (iv) the evaluation of the feasibility of the developed QIs. We identified eight domains of care for the management of patients with VA and the prevention of SCD: (i) structural framework, (ii) screening and diagnosis, (iii) risk stratification, (iv) patient education and lifestyle modification, (v) pharmacological treatment, (vi) device therapy, (vii) catheter ablation, and (viii) outcomes, which included 17 main and 4 secondary QIs across these domains. Following a standardized methodology, we developed 21 QIs for the management of patients with VA and the prevention of SCD. The implementation of these QIs will improve the care and outcomes of patients with VA and contribute to the prevention of SCD.


Assuntos
Cardiologia , Indicadores de Qualidade em Assistência à Saúde , Humanos , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...